Control Board DL-4-S-S & DL-4-P-S Troubleshooting PDF Print E-mail
Deltronics_img_17-2.jpg
Click Here for larger version






 DL-4-SS & DL-4-PS Quick Troubleshooting Guide

SYMPTOM TEST PROCEDURE
Runs non-stop at power up Check voltage at TP2 If high, replace 74C14. If low, replace Q2.
TD doesn’t run (dead) Press SW. and check voltage at TP2 If high, replace Q1 & Q2. If low, replace 74C14.
Ticket Meter does not work Replace Q3 and D3
TD coasts to a stop
Replace Q1
 Dispensing 1 1⁄2 to 2 1⁄2 tickets Check voltage at TP1 No Ticket: 0.1V to 0.7V Ticket: 10V to 12V If OK, replace 74C14 If NOT OK, replace H21A1