Control Board DL-4-S-S & DL-4-P-S Troubleshooting |
|
|
|
Click Here for larger version
|
DL-4-SS & DL-4-PS Quick Troubleshooting Guide
|
| SYMPTOM |
TEST PROCEDURE |
| Runs non-stop at power up |
Check voltage at TP2 If high, replace 74C14. If low, replace Q2.
|
| TD doesn’t run (dead) |
Press SW. and check voltage at TP2 If high, replace Q1 & Q2. If low, replace 74C14.
|
| Ticket Meter does not work |
Replace Q3 and D3
|
TD coasts to a stop
|
Replace Q1 |
| Dispensing 1 1⁄2 to 2 1⁄2 tickets |
Check voltage at TP1 No Ticket: 0.1V to 0.7V Ticket: 10V to 12V If OK, replace 74C14 If NOT OK, replace H21A1 |
|
 |
|